Secondary Operations: Spin Welding: Shear Joint Design
Critical Constraints
- T = Wall thickness
- Clearance ~0.002 in. (0.05 mm)
- Interference = 0.008 in. to 0.016 in. (0.20.4 mm)
- *Maintain ~0.01 in. (0.25 mm) gap between mating surfaces as shown after welding
Notes
- Ribs are spaced on periphery of flange for stiffness and gripping in spin welder.
|