Secondary Operations: Spin Welding: Flanged Shear Groove
Critical Constraints
- T = Wall thickness
- R = 0.05 in. (1.3 mm) radius
- Interference = 0.008 in. to 0.016 in. (0.20.4 mm)
- *Maintain ~0.01 in. (0.25 mm) gap between mating surfaces as shown after welding.
Notes
- Ribs are spaced on periphery of flange for stiffness and gripping in spin welder.
|